1. Help Center
  2. FAQs
  3. Automated Sampling / PAT

Which requirements must an autosampling system for bioprocesses have to fulfill?

An autosampling system for bioprocesses must fulfill several critical requirements to ensure that it operates effectively, maintains sample integrity, and integrates seamlessly with the bioprocessing workflow.

1. Sample Integrity and Sterility

  • Aseptic Sampling: The system must ensure that samples are taken aseptically to prevent contamination.

2. Accuracy and Precision

  • Consistent Sampling Volume: The system must deliver precise and accurate small sample volumes to ensure reliable analysis.
  • Repeatability: The system should consistently provide reproducible results across multiple sampling events.

3. Automation and Control

  • Automated Scheduling: The system should allow for programmable sampling schedules, enabling automated collection at predefined intervals.
  • Integration with Control Systems: It should integrate seamlessly with existing process control systems (e.g., SCADA, DCS) for real-time data acquisition and control.

4. Real-time Monitoring and Feedback

  • Real-time Data Transmission: The system should be capable of transmitting sample data in real-time to the process control system for immediate analysis and feedback.
  • Alarm Systems: Should include alarms for potential issues like sample line blockages, deviations in sample volume, or contamination risks.

5. Flexibility and Scalability

  • Multiple Sampling Points: The system should support multiple sampling points within the bioreactor or across different bioreactors.
  • Scalability: It should be scalable to accommodate different bioprocessing scales, from laboratory to pilot and full production scales.

6. Sample Preservation and Transport

  • Temperature Control: If necessary, the system should maintain samples at specific temperatures to preserve their integrity until analysis.
  • Minimized Hold Time: The system should minimize the time samples are held in the sampling lines to reduce degradation or changes in sample composition.

7. Compatibility with Analytical Instruments

  • Standardized Interfaces: The system should have standardized interfaces to connect with various analytical instruments like HPLC, GC, mass spectrometry, or spectroscopy.
  • Direct Injection: Where possible, the system should allow for direct injection of samples into analytical devices to reduce handling and potential contamination.

8. Maintenance and Cleaning

  • Easy Maintenance: The system should be designed for easy maintenance, with accessible components that can be replaced or cleaned without extensive downtime.
  • Automated Cleaning Cycles: Automated cleaning cycles (e.g., clean-in-place, CIP) should be available to ensure the system remains contaminant-free between sampling events.

9. User Interface and Software

  • Intuitive Interface: The user interface should be intuitive, allowing operators to easily set sampling schedules, monitor system status, and retrieve data.
  • Data Logging and Reporting: The software should support detailed data logging and generate reports for analysis and compliance purposes.

10. Robustness and Reliability

  • Durable Materials: The system should be constructed from materials resistant to the harsh conditions of bioprocessing environments (e.g., high temperatures, and corrosive chemicals).
  • Reliability: It must operate reliably over long periods, minimizing the risk of failures that could disrupt the bioprocess.

Conclusion

By fulfilling these requirements, an autosampling system for bioprocesses can ensure accurate, reliable, and sterile sampling, thereby supporting efficient and effective bioprocess monitoring and control. This enhances product quality, regulatory compliance, and overall process optimization.